BK-G33-1000KVA-Industrial Power Frequency UPS

PRODUCT PARAMETERS

The BK-G33 Series power frequency UPS is a medium-to-large power, three-input/three-output, power frequency double-conversion online intelligent fully digital UPS.
  • Advanced Design
  • High Power Factor
  • Strong Environmental Adaptability
  • Strong Overload Capacity
  • N+X Parallel Redundancy Design
  • Comprehensive Protection
  • Advanced Battery Management
  • Flexible Power Supply Modes
  • Rich Optional Accessories
  • Flexible Network Monitoring
Shipping Location: Shenzhen, China
Description
FAQs
Request A Quote

Description

Product Overview

The BK-G33 Series power frequency UPS is a medium-to-large power, three-input/three-output, power frequency double-conversion online intelligent fully digital UPS.

It integrates digitization and networking, featuring a robust information acquisition system, signal processing system, and comprehensive protection system.

As a sine wave online high-intelligence uninterruptible power supply, the BK-G33 Series ensures continuous operation of your critical equipment during power instabilities or outages

Notes:Industrial Power Frequency UPS is also as known as Uninterruptible Power System, Uninterruptible Power Supply, Transformer Based UPS, Online Low Frequency Uninterruptible UPS.

Application

The BK-G33 Series is widely used in the following sectors:

  • Micro data centers of small and medium-sized enterprises
  • Branches of large enterprises
  • Bank branches
  • Storage, network equipment, VoIP, and communication devices
  • Automation equipment and office terminals
  • Precision instruments and equipment

Product Features

  • Advanced Design

Online double-conversion design with zero phase-shift output isolation transformer ensures pure and stable power output.

Output power factor reaches 0.8, and input power factor up to 0.95 (with input filter), enhancing power efficiency.

  • Strong Environmental Adaptability

Wide input voltage and frequency range adapts to harsh grid environments, ensuring stable operation.

  • Strong Overload Capacity

Excellent output overload and short-circuit resistance (sustainable for 5 seconds) protects equipment from damage.

  • N+X Parallel Redundancy Design

Supports up to 6 units in parallel, including different models, improving system reliability and scalability.

  • Quasi-Modular Design

Independent heat sinks for power devices facilitate installation and on-site maintenance, reducing maintenance costs.

  • LBS Synchronization

Enables synchronization of two independent UPS systems, enhancing overall system reliability.

  • Generator Compatibility

Power Walk In slow start function reduces inrush current, protecting generators and UPS equipment.

  • Advanced Battery Management

Includes temperature compensation, battery life extension, discharge time prediction, and battery self-test, extending battery life and ensuring performance.

  • DSP Full Digital Control

Dual DSP digital control technology ensures system stability and reliability, improving control accuracy and response speed.

  • Automatic Power-On

Memory auto-start function enhances equipment usability.

  • Large LCD Display

Chinese/English LCD menu and real-time data display for easy monitoring of equipment status.

  • Flexible Network Monitoring

Standard RS232/RS485 communication interfaces, optional SNMP/JBUS/MODBUS dry contact cards for remote monitoring and management.

  • Intelligent Fan Speed Control

Adjusts fan speed based on internal temperature and load, reducing noise and energy consumption.

  • DC Start Function

Batteries can be used directly to start the UPS, convenient for use without mains power.

  • Comprehensive Protection

Includes power-on self-diagnosis, short-circuit, inverter over-temperature, battery under-voltage, battery over-charge, and surge protection.

  • Flexible Power Supply Modes

Offers normal mode, combined power supply mode, ECO mode, auto-start mode, and variable frequency mode to meet diverse business needs.

  • Rich Optional Accessories

Includes harmonic filters, bypass current sharing inductors, Class C lightning protection boxes, parallel cables, load synchronization (LBS) cables, SNMP/JBUS/MODBUS/dry contact cards, battery ground fault components, battery temperature sensors, and UPS room signals.

Technical Advantages

  • Stable and Reliable Power Protection

Effectively solves power problems such as outages, voltage fluctuations, and frequency variations, ensuring continuous operation of critical equipment.

  • Highly Integrated Digital and Networking Technologies

Facilitates management and monitoring, improving efficiency and reducing operational costs.

  • Strong Environmental Adaptability and Overload Capacity

Ensures stable operation under extreme conditions, enhancing equipment availability.

  • Flexible Parallel Redundancy Design and Multiple Power Supply Modes

Meets diverse business needs, improving system reliability and scalability.

Optional Accessories

  • Parallel Cable
  • Load Synchronization (LBS) Cable
  • SNMP/JBUS/MODBUS/Dry Contact Card

Specifications

ModelBK-G33-1000KVA
CapacityKVA/KW1000KVA/800KW (12 pulses)
Number of parallel machinesSupport up to 8 units
EfficiencyDouble conversion mode≥90%
Economy mode≥96%
InputMain InputRated Voltage380/400/415Vac
Voltage Tolerance±25%
Wiring3 phase 5wires(3L+N+PE) / 3 phase 4 wires(3L+PE)
Frequency Tolerance45~65Hz
Power Factor>0.95(Add filter)
Rated AC input380/400/415Vac
Bypass InputNominal Voltage380/400/415Vac
Rated AC input380/400/415Vac
Voltage Tolerance±25%
Wiring3 phase 5wires(3L+N+PE) / 3 phase 4 wires(3L+PE)
Frequency Tolerance±2%(±0. 5%, +1%, ±2%, ±3% Configurable)
OutputNominal Voltage380/400/415 ±1%
Power Factor≥0.8(Customizable)
Frequency ToleranceAutomatically track bypass frequency
Output THDSine wave THDV is less than 1% (pure linear load)
Switching time0
Efficiency≥95%
Output voltage regulation accuracySteady State±1%
Transient±5%
Overload Capacity105%~110%:60min Switch to bypass; 110%~125%:10min Switch to bypass; >125%: 10s Switch to bypass
Other parametersBatteryBattery voltage range384(Standard) / 396/408(Customizable)
EnvironmentalOperating Temperature-10~40℃
Storage Temperature-25~55℃(Battery not included)
Humidity0~95% (Non-condensing)
Altitude1500m, If the limit is exceeded, use the derated capacity in accordance with GB/T3859.2.
Noise Level<70dB@ 1 meters
Alarm functionAlarm rangeOutput overload, AC power abnormality, UPS failure, battery undervoltage
Alarm methodSound alarm
Protection functionOutput short circuit, overload, over temperature, battery undervoltage, output over-voltage and under-voltage, lightning protection (optional)
Communications and ManagementCommunication functionStandard configuration:RS232
Optional configuration:RS485/SNMP/Dry Contact
Display PanelLCD display / LED status indicator
StandardElectrical performance standardsYD/T1095-2017
Production ComplianceIEC 60529 ,IEC 60664 , IEC 60755
EMC/LVDEC62040-2,IEC62040-3
CertificateCE ROHS
Dimensions (W×D×H)Need to be customized
WeightNeed to be customized
Optional accessoriesSNMPSupport SNMP management and network management

FAQs

UPS stands for Uninterruptible Power Supply and is a device that provides a continuous supply of power to protect critical loads from power failures or fluctuations.

The main role of a UPS is to provide a backup power source to ensure that critical equipment can continue to operate when utility power is interrupted or unstable, avoiding data loss or equipment damage.

UPS is mainly divided into three types: offline, online and online interactive.

When choosing the power capacity of the UPS, you need to consider the total power demand of the load, it is usually recommended to choose a slightly larger than the total load power of the UPS to ensure sufficient standby time.

The standby time of a UPS depends on the battery capacity and load power. Standby time usually ranges from 10 minutes to several hours, and the specific needs can be determined according to the actual application scenario.